3/4200VS & 3/4000S Duct HOOD Cold HIGH RH #7427

(2 Reviews)
SKU: 7427 Duct Hood Cold 32/4200 HI RH
$995.00
In Stock

Usually Ships w/i 2-3 Days

Shipping Information:

UPS / USPS / FedEx

Custom duct hood for CellarPro 3200 / 4200 VS and 3000S / 4000S Split Refrigeration Systems. With this kit, the cold air intake/exhaust can be ducted up to 100 equivalent feet (50 feet per opening).

Required for use in moderate to high humidity environments.

The hood includes the ducting hood and remote display. Insulated 8-inch or greater (required from start to finish) ducting is NOT included.

  • Attaches easily to the front of 3200/4200 VS and 3000S/4000S Split refrigeration systems
  • Appropriate for Unconditioned / High-humidity environments
  • Provides access to cooling unit control panel and switches
  • Designed for easy hook-up to insulated 8" ducting (not included)
  • Both openings must be ducted (total of 100 equivalent feet) to/from the cellar
  • Maintains accurate temperatures inside the wine cellar
  • Includes our remote thermostat bottle probe (measures air or liquid temperatures)
  • Includes our remote control display kit

CellarPro 3200/4200VS & 3000/4000S Split Duct HOOD (Cold Side) HIGH RH #7427 (P/N 7427). Duct openings are designed to attach to 2 insulated 8-inch ducts (not included) for evaporator intake and exhaust. Custom design allows access to controls and switches on the face of the cooling unit.

Requires 9 inches of additional height at the front of the cooling unit.

Kit includes: Insulated duct hoods for cold side intake and exhaust, bottle probe and remote control display kit. Insulated 8-inch or greater (required from start to finish) ducting is not included.

The high fan speed setting MUST be used when our unit is ducted.

Please refer to the following resources before purchasing this kit:

  • This duct hood is required when the cooling unit will be installed in unconditioned environments, subject to the limitations listed in our Low RH vs High RH Duct Kit Chart. In some cases, the conditions are too extreme for any of our cold-side duct kits.
  • Use our ducting heat loss table and our duct correction table to correctly adjust the sizing of your cooling unit, because ducting will add to the thermal load of the cellar.
  • Refer to our Bottle Probe Operating Instructions to correctly set the cooling unit depending on how you're using the Bottle Probe