• Home
  • CellarPro 6200/8200 VS Duct KIT (Cold Side) High RH RETROFIT #16707

CellarPro 6200/8200 VS Duct KIT (Cold Side) High RH RETROFIT #16707

(0) Write A Review
Price: $825.00
Availability: In Stock
Usually Ships w/i 2-3 Days
Shipping Information:
FedEx / USPS / Saver
CellarPro 6200/8200 VS Duct KIT RETROFIT (Cold Side) HIGH RH RETROFIT (P/N 16707). Duct openings are designed to attach to 2 insulated 10-inch ducts (2 x 25' insulated flex ducts are included in this kit) for evaporator intake and exhaust. Custom design allows access to controls and switches on the face of the cooling unit.

The exhaust exits from the top, and the intake returns from the front.

Kit includes: Duct hood, 2 x 25-ft insulated 10-inch flex ducting, remote control display retrofit and bottle probe.

The high fan speed setting is required when our unit is ducted.

Bottle Probe Operating Instructions:.
  • When measuring liquid temperatures, the (HY) differential should be set at 1 degree (so that the wine liquid doesn't fluctuate more than 1 degree.)
  • When measuring air temperatures, the (HY) differential should be set at 4 degrees (the cooling unit will burn out prematurely if the unit cycles on'off every time the air temperature changes by 1 degree.)
  • The probe or bottle/probe must be located in a location with good air movement in order to correctly register the temperature changes inside the cellar.
  • When measuring air temperature with ducted systems, the ideal location for the bottle probe is in the return air register; when measuring air temperature with through-the-wall systems, the ideal location for the bottle probe is near the return air grill; when measuring liquid temperatures in bottles, the ideal location of the bottle is near the top of the racks with good airflow.
  • In all cases, it is recommended to check the actual cellar temperature against the display temperature when the bottle probe is first setup and subsequently whenever the location moves.
  • Refer to our Owners Manual for instructions how to change the HY differential


Be sure to refer to our ducting heat loss table and our duct correction table when sizing the cooling unit.
Custom duct kit RETROFIT for CellarPro 6200 / 8200 VS cooling units. With this kit, the cold air intake and exhaust each can be ducted up to 100 equivalent feet (50 feet per opening).
  • Attaches easily to the front (intake) and top (exhaust) of 6200/8200 VS refrigeration systems
  • Provides access to cooling unit control panel and switches
  • Designed for easy hook-up to 10" ducting
  • Both openings must be ducted (total of 100 equivalent feet) to/from the cellar
  • Bottle probe with 10' cord plugs into face of the cooling unit
  • Extra insulation for HIGH Humidity environments
  • Includes 2 x 25-ft 10-inch flex ducting
  • Designed for use when the cooling unit has shipped

Brand: CellarPro

Size: 14 3/16w x 4 11/16d x 27 1/2h (in)

Weight: 35 lbs

Capacity: 100 Equivalent Feet

Click on one of the following links for more information:

Ratings & Reviews

No reviews available

Be the first to Write a Review