Exclusively for our retail customers, we offer free shipping on most in-stock items that ship via FedEx Ground within the continental U.S. Requires a minimum order of $50. Excludes palletized items that ship on a truck via curbside or inside delivery, wine cooling units, WineKeeper products, oversized items, on-sale items, and items that ship directly from the manufacturer. May not be combined with other coupons, discounts or offers.

Please use promo code IWASHIPFREE at checkout.
Look for our "Free Shipping" burst (shown at right) on items that qualify for free shipping. If the burst is not shown on an item, it does not qualify for free shipping.


FedEx Ground Shipping Timing Map

Information Center > Buying Guides > Cooling Unit Buying Guides > 

CellarPro Cooling Systems - Glass Heat Loss

BTUH Adjustment Factor Per Square Foot of Glass

When using glass in a wine cellar, the heat loss through the glass must be considered when sizing the cooling unit.


Cellar Temperature
  Type of Glass
Single-Pane Double-Pane

Cellar Insulation

 

Ambient Temp

55°F Interior

 

60°F Interior

 

55°F Interior

 

60°F Interior

R12

  65°F 12.20   6.10   5.00   2.50
70°F 18.31 12.20 7.51 5.00
75°F 24.41 18.31 10.01 7.51
80°F 30.51 24.41 12.51 10.01
85°F 36.61 30.51 15.01 12.51
90°F 42.71 36.61 17.51 15.01
         

R19

65°F 12.60 6.30 5.40 2.70
70°F 18.90 12.60 8.10 5.40
75°F 25.20 18.90 10.80 8.10
80°F 31.50 25.20 13.50 10.80
85°F 37.80 31.50 16.20 13.50
90°F 44.10 37.80 18.90 16.20
         

R30

65°F 12.84 6.42 5.64 2.82
70°F 19.26 12.84 8.46 5.64
75°F 25.68 19.26 11.28 8.46
80°F 32.10 25.68 14.10 11.28
85°F 38.52 32.10 16.92 14.10
90°F 51.36 38.52 19.74 16.92

This table calculates heat loss using: 1) Ambient temperature where the glass is located 2) Desired temperature inside the wine cellar 3) R-Value of the cellar's insulation. To use this table, start by calculating the standard thermal load (in BTUH) using our other charts, the size of the cellar, the R-Value of insulation used in cellar construction, the ambient temperature outside the cellar, and the desired temperature inside the cellar. Multiply the square feet of glass times the adjustment factor in the above table, adding the resulting BTUH to the standard thermal load calculation.

If you have any questions, please don't hesitate to contact us and we'll be glad to help!

Example Cellar Calculation

Cellar Size 10'W x 10'D x 10'H

1000 Cubic Ft

Insulation

R19

Cellar Interior Temperature

55°F

Peak Ambient Temperature

85°F

Single Pane Glass 10'W x 10'H

Single Pane 100 Square Ft

Heat Loss Table Result 37.80*100

3780 Additional BTUH

Standard Thermal Load Result

3508 BTUH

Final Thermal Load of Cellar

7288 BTUH