Sizing Table: 1500-2000 cu ft - AH6500

ndefined

CellarPro Cooling Systems AH6500 Air Handler

55°F Cooling Capacity1

AH6500 - Low Fan Speed

BTUH 4923   Decibels2 47/52

AH6500 - Medium Fan Speed

BTUH 5350   Decibels2 51/57

AH6500 - High Fan Speed

BTUH 5771   Decibels2 59/62

Cellar Size1

 Ambient

Temperature
 Thermal Load (BTUH)
R12 R19 R30

1500

Cubic Feet

70°F4608 4346 4188
75°F482944804268
80°F504846134349
85°F526947464429
90°F549048794510
95°F571150144591
   

1750

Cubic Feet

70°F514148604691
75°F537650024775
80°F561251444861
85°F(5849)52884949
90°F(6085)54315035
95°F(6324)55765124
   

2000

Cubic Feet

70°F(5861)55565372
75°F(6116)57115466
80°F(6373)(5866)5558
85°F(6630)(6022)5653
90°F(6888)(6178)5748
95°F(7146)(6335)(5844)
 

CellarPro Cooling Systems AH6500 Air Handler

60°F Cooling Capacity1

AH6500 - Low Fan Speed

BTUH 5532   Decibels2 47/52

AH6500 - Medium Fan Speed

BTUH 5981   Decibels2 51/57

AH6500 - High Fan Speed

BTUH 6421   Decibels2 59/62

 

Cellar Size1

 Ambient

Temperature
 Thermal Load (BTUH)
R12 R19 R30

1500

Cubic Feet

70°F4055 3824 3685
75°F425039423756
80°F444240593827
85°F463741763898
90°F483142943969
95°F502644124040
   

1750

Cubic Feet

70°F452442774128
75°F473144024202
80°F493945274278
85°F514746534355
90°F535547794431
95°F556549074509
   

2000

Cubic Feet

70°F515848894727
75°F538250264810
80°F560851624891
85°F583452994975
90°F606154375058
95°F628855755143

The upper table is shaded to show how the AH6500 air handler cooling system will work at maintaining 55°F, and the lower how the AH6500 air handler cooling system will work at maintaining 60°F, inside the wine cellar using various fan speeds under various thermal loads. The thermal loads are derived from assumptions about the size of the cellar; the R-value in the six cellar surfaces (ie walls, floor and ceiling) and the ambient temperature outside the cellar.

CellarPro AH6500 wine cooling units are designed to maintain optimal wine storage temperatures in wine cellars up to 1750 cubic feet with adequate insulation, and can be operated with the condenser exposed to conditions up to 110°F. For more information, click on our performance and test data.

(1) The thermal loads above are calculated based on the R-Values shown for all walls and ceiling, and a concrete floor. Lower R-Values in the cellar (eg from glass doors) will increase the thermal load on the wine cellar and will require the cooling unit to operate at higher fan speeds. Warmer climates require higher insulation to enable the cooling unit to operate at lower fan speeds. To be certain that the thermal load won't exceed the capacity of the cooling unit, email your wine cellar specifications to us and we'll be glad to assist you.

(2) The decibels are listed for the evaporator / condensing unit, both ducted.