Exclusively for our retail customers, we offer free shipping on most in-stock items that ship via FedEx Ground within the continental U.S. Requires a minimum order of $50. Excludes palletized items that ship on a truck via curbside or inside delivery, wine cooling units, WineKeeper products, oversized items, on-sale items, and items that ship directly from the manufacturer. May not be combined with other coupons, discounts or offers.

Please use promo code IWASHIPFREE at checkout.
Look for our "Free Shipping" burst (shown at right) on items that qualify for free shipping. If the burst is not shown on an item, it does not qualify for free shipping.


FedEx Ground Shipping Timing Map

Information Center > Buying Guides > Cooling Unit Buying Guides > 

Buying Guide: 400-800 cu ft - 3200VS

Light grey is low fan speed, Medium grey is medium fan speed, Dark grey is high fan speed, Blue is beyond capacity

Cooling Unit Capacity—55°F

3200VSi - Low Fan Speed
BTUH 2487    Decibels 54

3200VSi - Medium Fan Speed
BTUH 2876    Decibels 58

3200VSi - High Fan Speed
BTUH 3040    Decibels 66

Cellar Size

  Ambient
Temperature
  Thermal Load (BTUH)
R12   R19   R30

400

Cubic Feet

70°F 1810   1676   1596
75°F 1921 1744 1636
80°F 2033 1811 1676
85°F 2146 1879 1717
90°F 2256 1946 1758
95°F 2369 2015 1800
Divider        

500

Cubic Feet

70°F 2111 1958 1867
75°F 2238 2035 1913
80°F 2366 2112 1958
85°F 2494 2190 2006
90°F 2622 2267 2052
95°F 2750 2345 2100
Divider        

600

Cubic Feet

70°F 2359 2192 2092
75°F 2500 2278 2143
80°F 2639 2362 2194
85°F 2779 2446 2244
90°F 2920 2531 2296
95°F 3040 2616 2347
Divider        

700

Cubic Feet

70°F 2630 2450 2340
75°F 2782 2542 2395
80°F 2984 2634 2452
85°F 2725 2506
90°F 2818 2562
95°F 2910 2617
Divider        

800

Cubic Feet

70°F 2902 2711 2596
75°F 3040 2807 2653
80°F 2904 2712
85°F 3001 2771
90°F 2828
95°F 2887
Divider        

Cooling Unit Capacity—60°F

3200VSi - Low Fan Speed
BTUH 2663    Decibels 54

3200VSi - Medium Fan Speed
BTUH 3084    Decibels 58

3200VSi - High Fan Speed
BTUH 3258    Decibels 66

Cellar Size

  Ambient
Temperature
  Thermal Load (BTUH)
R12   R19   R30

400

Cubic Feet

70°F 1593   1475   1404
75°F 1690 1535 1440
80°F 1789 1594 1475
85°F 1888 1654 1511
90°F 1985 1712 1547
95°F 2085 1773 1584
Divider        

500

Cubic Feet

70°F 1858 1723 1643
75°F 1969 1791 1683
80°F 2082 1859 1723
85°F 2196 1927 1765
90°F 2307 1995 1806
95°F 2693 2302 2065
Divider        

600

Cubic Feet

70°F 2314 2156 2059
75°F 2448 2237 2108
80°F 2582 2318 2158
85°F 2446 2152 1975
90°F 2570 2227 2020
95°F 2693 2302 2065
Divider        

700

Cubic Feet

70°F 2314 2156 2059
75°F 2448 2237 2108
80°F 2582 2318 2158
85°F 2716 2398 2205
90°F 2850 2480 2255
95°F 2984 2561 2303
Divider        

800

Cubic Feet

70°F 2554 2386 2284
75°F 2694 2470 2335
80°F 2834 2556 2387
85°F 2976 2641 2438
90°F 3116 2725 3489
95°F 3258 2811 2541
Divider        

The tables are shaded to show how the 3200VS cooling unit will work at maintaining 55°F (upper table) and 60°F (lower table) inside the wine cellar, using various fan speeds and thermal loads. The thermal loads are derived from assumptions about the size of the cellar, the R-value in the six cellar surfaces (ie walls, floor and ceiling), and the ambient temperature outside the cellar.

CellarPro 3200 wine cooling units are designed to maintain optimal wine storage temperatures in wine cellars up to 800 cubic feet with adequate insulation, and can be operated with the condenser exposed to conditions up to 115°F. For more information, click on our 3200VS performance and test data.

The thermal loads above are calculated based on the R-Values shown for all walls and ceiling, and a concrete floor. Lower R-Values in the cellar (eg from glass doors) will increase the thermal load on the wine cellar and will require the cooling unit to operate at higher fan speeds. Warmer climates require higher insulation to enable the cooling unit to operate at lower fan speeds. To be certain that the thermal load won't exceed the capacity of the cooling unit, email your wine cellar specifications to us and we'll be glad to assist you.